China Automotive Networking Sprinklers Catalog A total of China's Ministry of Industry and Information Technology Inc. Sprinkler Trucks Automobile Bulletin All 10 Categories 253 Manufacturers 227 Sprinkler Brands 3071 Sprinklers Product Information, Latest Sprinklers Announcement, Environmental Notices, Fuel Bulletins, Free Announcements, pictures, news, and price information on the most timely sprinkler quotes.

Overview
Dongzheng Dongfeng Furica sprinkler refers to the Dongfeng company's Dongfeng Furika II chassis

The sprinkler made by adding water tanks, pumps, etc., carries 4-6 cubic meters of water. Mainly used for various road flushing, trees, green belts, lawn greening, construction of roads, factories and mines, and high-rise building flushing. With sprinkler, dust, high and low spray, pesticide spraying, guardrail flushing and other functions.


Basic parameters
Product Name: Dongzheng Dongfeng EQ1060 Furica Water Sprinkler Size: 5850×1950×2250 (mm)
Chassis model: EQ1060TJ20D3 Carriage size: ×× (mm)
Total weight: 4495 (kg) Approach/Departure angle: 15/13 (°)
Rated weight: 1485 (kg) Front suspension/rear suspension: 1032/1518 (mm)
Curb weight: 2880 (kg) Maximum speed: 95 (km/h)
Engine: CY4102-C3F, YN27CR, YN30CR, SD4BW70-3R
Displacement: 3856 2659 2672 2977 2545 (ml) Power: 70 66 66 76 70 (kw)
Manufacturer: Dongfeng Chaoyang Diesel Engine Co., Ltd. Guangxi Yuchai Machinery Co., Ltd. Chengdu Yunnei Power Co., Ltd. Chengdu Yunnei Power Co., Ltd. Jiangsu Sanda Power Machinery Group Co., Ltd.
Emission standards: GB3847-2005, GB17691-2005 State III
Number of axes: 2 Front track: 1506 (mm)
Wheelbase: 3300 (mm) Rear track: 1442 (mm)
Number of tires: 6 Tire specifications: 7.00-16, 6.50-16, 7.00R16, 6.50R16
Fuel Type: Diesel Spring Number: 8/9+5,6/8+4
Axis load: 1855/2640 Cab number 2
Vehicle Remarks: Tank dimensions (length × long axis × short axis) (mm): 3200 × 1100 × 655. The effective volume of the tank: 1.55 cubic meters. Transport medium name: Water; medium density: 1000 kg/m3.


Function and description
☆ There is a duck-billed or round-headed nozzle in front of the sprinkler, a cylindrical sprinkler nozzle or a showerhead nozzle behind the sprinkler, a working platform at the rear, and a monitor. There are 8 nozzles on the back.
☆ Sprinklers, green spray vehicles for the special features: green sanitation function, suitable for urban sanitation of residential plants, the use of quality leading high-power dedicated sprinkler pumps. After the rush (spray), sprinkle, with side spray (shower), with the back of the platform, install green sprinkler on the platform (cannon with heavy rain, moderate rain, drizzle, fog can be adjusted), with suction pipe, with fire Joints, with self-flow valve, self-priming self-discharge, optional 20 meters green spray reel, high-altitude operations, truck crane cargo and other functions.
☆Operating system: The engine is mainly driven by the engine. The PTO installed on the gearbox drives the sprinkler pump. The sprinkler pump generates power to spray the liquid inside the tank through the pipe network. Working range: Self-priming height: ≤7m, Sprinkling width: ≥14m, Maximum range: ≥28m; Adjustable into a column with a range of ≥28m; It can also be adjusted to a mist with a range of ≥15m.
Water absorption
Dongfeng Tianjin sprinkler
(1) The sprinkler should be as close as possible to the operating point and parked.
(2) Open the side door of the walk-in box and take out the water-absorbing rubber hose so that it swings back without bending.
(3). Pull the water suction hose into the water as deep as possible to ensure that the end of the pipe is 300mm below the liquid level during the operation.
(4). Push the four-way valve handle vertically to the ground.
(5). Hitch the transmission to neutral, then start the engine, separate the clutch, pull the power take-off switch backwards to pull the file, and the pump starts to run.
(6) The operator can observe the upper part of the rear head. When the liquid level reaches the middle of the sight glass, the operator should be notified that the coworker should quickly pull the suction hose away from the water or close the four-way valve.
(7) After retracting the hose, return it to the walk-in box and close the side door.
(8) Driving the water truck away from the pumping location
2. Spraying operation
(1) Pull the rear handle of the four-way valve to parallel with the ground, open the ball valve you want to spray (front punch, rear spray, side spray, shower), then start the engine and put the transmission into the gear, take the power take off device. The switch pulls back and pulls the gear, then the clutch is disengaged and the pump starts to run.
(2) After the water in the tank has been sprinkled, the driver should push the power take-off handle forward to remove the gear, and the sprinkling pump stops running.


Operation method

1. Power take-off device 2, water pump 3, water tank 4, communication valve 5, fire ball valve 6, filter net 7, front flush valve 8, water spray valve 9, side spray valve 10, rear shower valve 11, and water spray gun 12. Tank cover 13, front punch 14, side spray lotus head 15, rear sprinkler 16, anti-rotation plate ABC, three-way four-position valve
First, add water
1. Open the car to a predetermined position so that the mouth of the tank is aligned with the tap of the tap. Open the cap and tap water to add water.
2. When the water is collected in the field, water can supply water to the tank through the water pump. Its operating procedure is: connecting a rubber hose to the surface water source at the four-position three-way valve A to make the three-way ball valve A and C communicate, closing the ball valve 7, 8, 9, 10, opening 4, and stepping on the clutch to open the power. Switch, slowly release the clutch (do not be too fast, otherwise it will damage the power take off or gearbox), so that the water pump starts working, you can add water to the tank, stop the switch back to work.
Second, sprinkle water
Connect the c and b of the three-way and four-position valve, close the valve 4, open 7, 8, 9, 10 as needed, where 7 is the forward punch switch for flushing the road and 8 is the water gun switch (can be used for emergency fire fighting. Long-distance watering of flowers and trees). 9 is a side spray switch, which can water the roadside flowers and plants. 10 is a post-sprinkler switch for watering the pavement.
After the water in the water tank is sprinkled, separate the clutch and remove the power take-off device.
Third, watering flowers, emergency fire
Turn on the three-way and four-position ball valves, B and C are connected, 4, 7, 8, 9 and 10 are closed, and then a hose is connected at 5, and the other end of the hose is connected to a water gun. Using the gravity of the water, the water can be flowed freely. . Can also be hung on the power take-off pressure emergency fire or long-distance watering flowers and trees.
IV. Active pump station
Turn on the three-way four-valve A and C. Connect the suction hose to the A port, close the 4, 7, 8, 9, and 10, open the valve 5, and take out the water pipe at port 5 so that the water pump can start working. The pumping of the ground to the second floor serves as an active pumping station. [1]


Sprinkler precautions
1. When the sprinkler uses the river ditch or pond as a water source, be careful that all the ends of the suction pipe are not in the water. In order to avoid inhaling stones or more sand and drift debris, the suction pipe end is generally provided with a filtering device, and it is forbidden to remove the filtering device during the water absorption. If the water source is shallow, it is necessary to dig up the water absorption area in advance so as to ensure that it does not contain impurities and air. The water pump requirements for different sprinklers are different. The clean water pump requires no impurities in the water. The turbid water pump requires no stones and excessive sediment in the water.
2. Each time the centrifugal pump absorbs water, a certain amount of water must be added to the pump. After the addition, the water inlet must be closed. When the self-priming pump is used for the first time, it is necessary to add water, and it is unnecessary to add water afterwards.
3. The water inlet pipe system must maintain a certain degree of vacuum before it can suck water into the tank. The inlet pipe system must be sealed reliably, the hose can not be damaged, the hard pipe can not have cracks, otherwise it will have a phenomenon of air leakage, which will result in the situation that it cannot suck water.
4. When the sprinklers are in front of the water or before the water is sprayed, the power take-off device must be parked.
5. Before the advent of winter, the water in the pumps and pipes should be vented to prevent freezing. In northern China, which is generally no longer under construction during the harsh winter season, the water in the pumps and pipes will be drained immediately after construction is completed to prevent future problems.
6. The sprinkler front nozzle is located at a low position, close to the ground, the spray pressure is greater, and can be used for flushing the road surface; the rear nozzle position is relatively high (the sprinkler rear nozzle is generally installed one on each side), and the spray surface is wide, and can be used for highway construction and watering. When using the rear nozzle, the front nozzle should be closed; when using the adjustable nozzle, the width of the water can be adjusted as needed. The wider the sprinkler width, the less the amount of intermediate overlap and the more uniform the sprinkler density.
7. Lubricate the lubrication points of the transmission assembly on a regular basis during use, and frequently tighten the coupling points to ensure normal use.
8. The sprinkling tank storage tank is provided with a discharge pipe. The inlet of the pipe is the lowest point of the tank. After a period of use, the discharge pipe switch should be opened periodically to remove the accumulated debris from the tank until the water becomes clear.


parameter
Vehicle name:
Dongfeng Furika sprinkler
Chassis Model: EQ1060TJ20D3 Rated Quality: 3250, 3315 (Kg)
The main technical parameters of the product
product name:
Dongfeng Furika sprinkler
Dimensions:
5990X1960X2380(mm)[2]
Chassis model:
EQ1060TJ20D3
Carriage size:
XX (mm)
Total quality:
6495 (Kg)
Approach/Departure angle:
17/13 (°)
Rated quality:
3250,3315 (Kg)
Front suspension and rear suspension:
1032/1658(mm)
Maintenance quality:
3050 (Kg)
The maximum speed:
90 (km/h)
Vehicle remarks:
Effective volume of the tank: 3.4 cubic meters; dimensions of the tank (long/long axis/short axis) (mm): 3300/1500/1000. When the number of passengers in the cab is 2 persons, the rated load is (kg) 3315; when the number of passengers in the cab is 3, the rated load is (kg) 3,250. With the optional chassis cab. Protective material: Q235 carbon steel, connection method: the left and right side and the lower part of the protection are welded connection, the rear protection section size (mm): 220 × 50 × 5, the rear protection from the ground (mm): 400.
Chassis parameter parameters
Chassis model:
EQ1060TJ20D3
Fuel type:
Diesel
Axis number:
2
Front track:
1506(mm)
Wheelbase:
3300
Rear track:
1466(mm)
Cab ride number:
2,3
Number of springs:
8/9+5,6/8+4
Number of tires:
6
Axle load:
2595/3900
Tire specifications:
7.00-16, 6.50-16, 7.00R16, 6.50R16
Emission Standards:
GB3847-2005, GB17691-2005 State III
Effective volume of the tank: 3.4 cubic meters; dimensions of the tank (long/long axis/short axis) (mm): 3300/1500/1000. When the number of passengers in the cab is 2 persons, the rated load is (kg) 3315; when the number of passengers in the cab is 3, the rated load is (kg) 3,250. With the optional chassis cab. Protective material: Q235 carbon steel, connection method: the left and right side and the lower part of the protection are welded connection, the rear protection section size (mm): 220 × 50 × 5, the rear protection from the ground (mm): 400.
Drivers drive a sprinkler on the road, and they must maintain a high degree of vigilance to more effectively ensure the safety of the car. Now that there are more and more cars on the road, and some cars are fast, they are prone to accidents if they are not careful. .
There are many sprinkler drivers who have accidents while driving because they do not pay attention to small details. They overlooked some details and buried hidden dangers.
I believe that many sprinkler drivers have encountered such a thing. When they drive a car, the car will run away and start to lean towards the track of the motor vehicle. Driving a car is fast. Things like this are very common in driving, because with the increase of driving time, people's attention will decrease, so when there is a small amount of deviation, people will not find it. In spite of this, we must avoid this type of incident in order to better ensure the safety of the sprinkler. Sometimes when driving at night, the driver will turn on the high beam when needed, but will forget to turn it off after use. This is one of the details that cannot be overlooked, because the incorrect use of high beam will flash to the driver’s eyes. Easy to cause car accidents, so sprinkler drivers must pay attention to the use of the lights, including the turning lights and brake lights of the sprinkler, and do not give wrong guidance to others.


Hot Air Popcorn Machine

Hot Air Popcorn Machine,Nostalgia Popcorn Making,Hot Air Popcorn Machinery,Hot Air Popcorn Maker

Jinan RuiHan Trading Company Limited , https://www.ruihangroup.com